AX-NURC-2004 Universal Expansion Controller
NURC Panels per UNC-500 /
AX-UNC100
3
NURC Panels per NC-100
(legacy)
4
D-Net Communications to NC-100
Speed
Distance
Cable Type
Supervised RS-485
38.4 Kbps
4,000 ft (1,200m)
18 AWG, 2 conductor, twisted, stranded, shielded
Access Points (Readers / Keypads):
Distance
Cable Type
2 with LED and Buzzer control
Max 500 ft (150 m)
20-22 AWG, 6 to 8 conductor, stranded, shielded
Programmable Supervised Inputs:
Input Supervision
Distance
Cable Type
4
For state monitoring (1 or 2 resistors)
Max 1,000 ft (300 m)
20 – 22 AWG, 2 conductor
Programmable Outputs:
Output Mode
2 SPDT 5A @ 30 VDC, dry contacts
2 Electronic drivers, 12 VDC max, 100 mA
Programmable Fail Safe / Fail Secure
Power Requirements 1.5A at 12VDC transformer (not included)
Simultaneous Card Formats
per Panel 5, All Wiegand compatible readers supported
Recommended Back-up Battery 12 V, 7 AH lead, acid or gell cell (not included)
SPECIFICATION